Air Conditioners play 50% of the role in energy bills. Often Air Conditioners are left turned on, when not needed, which wastes a large amount of energy. CoolSense helps you cut costs by turning Off ACs when not needed!
Introducing CoolSense - World’s first sensing controller for Energy Savings of your Air Conditioners
CoolSense Smart Controller controls Air Conditioner by generating pre-learnt IR commands of Air Conditioner or by cutting ON/OFF AC Mains supply of Air Conditioner. It consists of RTC, RF Receiver, WiFi Module, IR Learner, IR Generator & Dry Contact.
It will connect with a WiFi Router. It can be installed by fitting on the front/sides/top of the ACs or in Distribution Board (DB).
CoolSense works with three components:
CoolSense Smart Controller works with a Smart phone App.
1. Connect with CoolSense
'Connect' via CoolSense's own Hotspot
OR
'Add' Network Configuration & Connect via Local Network or Internet
2. Set your preferences (Set time delay of motion sensor, temperature threshold, time schedule or Control from anywhere using App)
3. Monitor & Control from Anywhere in the World
Set it & Forget it!
Forget hassles of controlling Air Conditioners. Yes, that’s smart!
All data of schedules saved in CoolSense Smart Controller (hardware)
By Connecting the CoolSense with WiFi Internet, control and monitor CoolSense from anywhere using App over internet.
Device Sharing - Share Device with your colleagues, engineers, teams, friends or family
Using the CoolSense Smart Phone App, You can set any schedule using parameters of Real-Time Clock, Human (PIR) Motion Sensor & Temperature Threshold to trigger Air Conditioners via IR Commands (for e.g: Temperature Change, Swing Control, Fan Speed, etc.) or Power Supply cut-ON/OFF. You can analyze system parameters, monitor and control your Air Conditioners from anywhere in the world over internet.
Motion
Dependent Control
Time
Based control
Temperature
Dependent Control
Plug & Play
7-day Scheduling
Smartphone App for
Quick Configuration
In-App Password
Protection
In-App Activity Logs
Universal
IR Compatibility
Remote Monitoring
Control using
Internet
Wired PIR Motion
Sensor Compatibility
System Arm/Disarm
30 Schedules
Quick ROI
24x7 Support
Intelligent
Energy Savings
Hands-Free
Control
1 - Year Warranty
“Easy to Install, Simple Configuration, Smart Control”
Parameters | Description |
Product Code | CS-MTTIRL-A |
Supply Voltage | 110 - 240 VAC |
Frequency | 50/60 Hz |
Programming | Based on Motion Sensor Delay, Real-Time Clock and Room Temperature Cut-On Threshold |
Max. Schedules Count | 30 |
Trigger Modes | Motion Sensor, Room Temperature Sensor, Real-Time Clock and Smartphone App (Manual) |
OFF Hours | Programmable |
Weekly Off | User Defined |
Alternate Mode | Yes |
Number of Operating Modes | 5 |
Mode Description |
Motion Sensor Based Control Room Temperature Based Control Real-Time Clock Based Control Smart Mode: Combination of 2 or more modes App Based Control |
Power Reserve from Factory | 10 Years for Real-Time Clock |
Output |
Relay Output Infrared Commands Output |
InfraRed Output |
Universal IR Commands (of Air Conditioner IR Remote)compatibility |
Relay Contact rating |
5 A @ 240 VAC (*As per load, suitable contactor required) |
Operating Temperature |
-10°C to + 50°C |
Storage Temperature |
-10°C to + 60°C |
Humidity (Non Condensing) |
95% (Rh) |
Mounting |
Base / DIN Rail |
Device Protection |
Under Voltage Over Voltage EMF |
Connectivity |
WiFi |
Hotspot Range |
20-30 m (Outdoor Range) |
WiFi Specifications |
Standards - FCC/CE/TELEC/SRRC Protocols - 802.11 b/g/n/e/i Frequency - 2.4 GHz - 2.5 GHz (2400 MHz - 2483.5 MHz) Tx Power - 802.11 b: +20 dBm 802.11 g: +17 dBm 802.11 n: +14 dBm 802.11 b: -91 dbm (11 Mbps) 802.11 g: -75 dbm (54 Mbps) 802.11 n: -72 dbm (MCS7) |
Hardware |
32-Bit Microcontroller 512 KB EEPROM CPU @ 80 MHz |
Software |
Wi-Fi Mode - station/softAP Security - WPA/WPA2 Encryption - WEP/TKIP/AES Firmware Upgrade UART Download / Over-The-Air (OTA) (via network) Software Development Supports Cloud Server Development / Firmware and SDK for fast on-chip programming Network Protocols - IPv4, TCP/UDP/HTTP/MQTT |
Remote Access |
via Internet |
Motion Sensor Type |
Passive InfraRed (PIR) |
No. of Motion Detectors in Sensor |
3 |
Detection Range |
360° |
Detection Distance | 20 m max. |
Detection Motion Speed | 0.6 - 1.5 m/s |
Motion Sensor Power Source | 220 V - 240 VAC @ 50 Hz |
CoolSense is a product of MEMIGHTY. It initiated as an idea to develop customized energy saving solution for corporates and soon set to be developed into a full- fledged energy saving solution for all Public Air Conditioner applications. Since its inception, it has changed the way ACs are controlled in more than 250 Corporates, Schools, Hospitals. Hotels, etc.
Often when people leave their offices/cabins, they leave their Air Conditioners turned ON. This can extend for more than 2-3 hours which leads to high energy wastage.
Often in public Air Conditioner applications, people set the temperatures of their ACs lower than 18-20 °C which doesn’t let Air Conditioner to cut-off compressor because room temperature rarely (seldom) reaches at such low temperature range, this leads to high energy wastage.
Pro Tip: Standard AC running temperature is 24 °C (± 2 °C) as recommended by American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE)
In public Air Conditioner applications, people often leave ACs running during break hours, after office hours, before office hours, etc. which leads to energy wastage.
With custom delay time setting and re-triggering using CoolSense App, CoolSense can accurately detect whether someone is present in the room or not.
In-built Room Temperature Sensor in CoolSense is used to set threshold temperature for turning ON the Air Conditioners. The threshold defines whether Air Conditioner is required to turn ON or not. If Room Temperature is greater than the threshold, then only ACs are turned ON (provided human motion is detected). This is useful in changing seasons.
With In-built RTC in CoolSense you can schedule when Air Conditioners shall be turned ON and schedule turn OFF. This eliminates misuse of Air Conditioners in OFF hours.
Scene - 1: School/Colleges - Assume that School timings are from 7:30 AM to 1 PM, during this time, if temperature is more than 25 degree Celsius and somebody is present in the classroom then AC must turn On at 24 degree Celsius else remain Off… Outside of the schedule, AC remains Off!
Scene - 2: Private Offices - Assume that Office timings are from 9 AM to 5 PM, during this time, if person is in the cabin then AC turns On. If the person exits the cabin & returns within pre-set delay time (For e.g: 30 minutes) then AC remains ON. It turns OFF if person doesn't return within 30 minutes. Outside of the schedule, AC remains Off!
Scene - 3: Bedroom - Assume that you enter your bedroom after 9 PM, AC turns On on turbo cooling; At midnight, AC is triggered to run on 24 degree celsius. At the stroke of dawn, AC turns Off… Outside of the Schedule, AC remains Off!
Let’s save ‘wasted’ energy of Air Conditioners with CoolSense!
CoolSense - Smart. Intelligent. Savings.
CoolSense is ideal for any situation where air conditioning is left running in unoccupied rooms, unnecessarily increasing running costs, maintenance costs and wear and tear.
CoolSense is specifically designed to reduce energy wastage by automatically turning off air conditioning in rooms left empty.
CoolSense will sense when the air conditioner is running and scan the room to check that it is occupied. When no occupancy has been detected for a pre-set time (adjustable between 15, 30, 45, 60 minutes (or more)) a signal will be transmitted to the air conditioner to switch it off.
CoolSense uses passive infrared technology and smart software to scan the air conditioned room for occupancy. If the room is left empty then after a pre-set time, CoolSense will automatically switch the AC off by sending an IR signal that emulates the ‘Off’ signal of the AC remote. Thus ensuring that the AC shuts down correctly each and every time.. CoolSense also has other unique functions to customise the operating settings to precisely suit each application, including Day/Night settings to prevent accidental switch offs when occupants are asleep.
CoolSense App is used to schedule operation of Air Conditioners and also it is used to control ACs from anywhere in the world using internet. CoolSense App helps in configuration of all parameters of CoolSense Smart Controller such as of Human Motion Sensor, Room Temperature Sensor, Real-Time Clock, IR Commands learning and connectivity modes
Coolsense is designed to work on all air conditioners.
You can use the Power supply cut-ON/OFF functionality of CoolSense Smart Controller for controlling your Air Conditioner in case of no infrared control.
Each air conditioner head unit needs its own CoolSense.
Yes. CoolSense has variable settings to suit all types of rooms and all types of situations including bedrooms.
CoolSense can be set for bedrooms by configuring real-time clock schedule for one’s bed time. When a person enters bedroom after the scheduled time, CoolSense will turn ON Air Conditioner using human motion detection. The Sensor delay for rooms such as bedrooms can be set for more than 2 or 3 hours (as suitable) to accommodate least motion detections when people are asleep and not moving much. This functionality justifies schedules for both day or night as some people may take a nap during the day time.
CoolSense is straight forward to install and set up. Because the AC units are 240 volts they must be installed by either an air conditioning technician or an electrician. Typically it takes between 20 and 40 minutes to install and set up CoolSense Smart Controller. Please visit the How to Install link or call us / email for more support.
CoolSense comes with a Long Range, high sensitivity PIR Motion Sensor (3 Detector, 360°) with a range of 8-10 meters. For larger rooms, extra sensors can be added for accommodating larger sensing range.
Any room that has an individual air conditioning unit. Including holiday units, hotel bedrooms, holiday rental properties and houses, commercial buildings, corporates and individual offices, staff and student accommodation meeting rooms, domestic houses and home offices etc. Installing a CoolSense will save energy and therefore money.
No, CoolSense remembers its settings and simply carries on functioning as normal once power is restored.
CoolSense has a 12 month full replacement warranty.
With a typical air conditioner costing over 60 cents an hour to run it won't take long to pay for itself if you stop cooling and heating empty rooms!!
Experts recommend that for maximum comfort, the temperature of rooms should be 24-26 °C. Additional cooling results in energy wastage. By raising the temperature setting on your air conditioner by just one degree, you can drop your power use by up to 10 per cent. We recommend that you use the CoolSense Smart Controller IR based temperature change functionality to optimise the running temperature of your air conditioning.